Product name: Interface material of network measuring instrument: oxygen-free copper plated with nickel,
Power supply specification: 9V laminated battery shell material: environmentally friendly PVC,
Gauge: 100X60X26mm, 100X25X26mm
Usage of tester
1. function
1. Test the unshielded network cable. Lights: 1, 2, 3, 4, 5, 6, 7, 8:
2. Test the shielded network cable, and turn on the lights: 1, 2, 3, 4, 5, 6, 7, 8, G;
3. Test the telephone line and turn on the lights: 1, 2, 3, 4, 5, 6;
Right to the above line (right). Scan and test root by root (pair). Distinguish and determine which (right) wrong line is short-circuited and open-circuited.
2. Usage
1. Turn the power supply to the ON position for fast scanning test (S is the slow test file).
No.1, No.2, No.3, No.4, No.5, No.6, No.7, No.8, and No.G of the main tester are flashing, indicating that the machine is in normal working order.
2. Insert the terminal plugs to be tested into the corresponding ports of the main tester and the remote tester. (Try to keep the plug and socket in good contact. Otherwise, it will affect the scanning result.) If all the line ends of the test line are good; Main tester and remote test. Indicator lights 1, 2, 3, 4, 5, 6, 7, 8, G are flashing one by one. If you test the unshielded wire, the G light of the remote machine will not flash.
The correct wiring is the flashing network cable:
Master tester: 1-2-3-4-5-6-7-8 Remote tester: 1-2-3-4-5-6-7
top
The six-core telephone line flashes when the connection is correct.
Master tester: 1-2-3-4-5-6-7-8 Remote tester: 1-2-3-4-5-6
Legend of flashing lights when four-core telephone line is connected correctly
Master tester: 1-2-3-4-5-6-7-8 Remote tester:-2-3-4-5-
When the two-core telephone line is connected correctly, the legend of flashing lights will be broadcast live.
Master tester: 1-2-3-4-5-6-7-8 Remote tester:-3-4-
3. If the wiring is incorrect, the indicator light display mode
When the network cable is short-circuited (for example, when Line 4 and Line 5 are short-circuited), the No.4 lamp and No.5 lamp of the main tester and the remote tester are not lit. When several lines are short-circuited, the corresponding ones of the main tester and the remote tester will not light up.
Main tester: 1-2-3-6-7-8 Remote tester: 1-2-3-6-7-8